PL & Raman Simultaneous Mapping System |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| This Raman and PL simultaneous mapping system performs Raman spectroscopy and photoluminescence (PL) measurements simultaneously at the same spot, enabling mapping measurements of samples. By simultaneously performing Raman measurements with a near-infrared laser and photoluminescence measurements with an ultraviolet laser, the system allows correlation analysis at the same position between structural information of semiconductor materials, such as crystallinity, stress, and composition, and optical properties, such as emission characteristics and defect levels. In addition, by switching the optical system, the system also supports Raman measurements with ultraviolet laser excitation. Because Raman and PL mapping data can be acquired at identical coordinates, the system is an effective analytical tool for research and development, materials evaluation, and failure analysis of semiconductor materials and optoelectronic semiconductor devices. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
■Features |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
1. Simultaneous Raman and photoluminescence mapping measurements 2. Equipped with three lasers: deep ultraviolet, ultraviolet, and near-infrared 3. A spectrometer with zero astigmatism makes the system more compact than our previous models. 4. A back-illuminated CCD with etaloning suppression enables high-sensitivity measurements. 5. A large, high-precision motorized stage with a 200 mm stroke enables mapping of 6-inch wafers. 6. The polarization of the incident and collected light can be controlled for Raman measurements, and the polarization of the collected light can be controlled for photoluminescence measurements. 7. The following measurements are available: • Simultaneous 325 nm-excited PL spectroscopy and 785 nm-excited Raman spectroscopy • Simultaneous 266 nm-excited PL spectroscopy and 785 nm-excited Raman spectroscopy • 266 nm-excited Raman spectroscopy • 325 nm-excited Raman spectroscopy 8. Computer-controlled operation and measurement |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
■Basic Specifications |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
*Specifications and appearance are subject to change without notice for product improvement. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||